Multi-level Coil Bundle for Efficient Cargo Tank Heating

时间:2024-08-31

Gojko Magazinović

Abstract This paper proposes and analyzes a novel heating coil bundle with the tubes arranged in a multi-level manner. The bundle generates a heated cargo large-scale circulation that enables a superposition of the circulation-driven forced convection on the buoyancy-driven natural convection, providing a more efficient mixed convection heat transfer mechanism. A simulationbased comparison of the proposed design and the conventional design is provided. The test case comprising an actual tank heating of an RMH 45 residual fuel oil by an 8-bar steam is simulated by a finite volume method and an OpenFOAM computational fluid dynamics software. The simulation results reveal that a 47.1% higher average heat transfer coefficient may be achieved, allowing a 32.0% reduction of the required heating coil area.

Keywords Coil bundle · Cargo heating · Circulation · Mixed convection · Finite volume method · OpenFOAM

1 Introduction

Heating coils are a necessary piece of equipment in the majority of oil tankers. Their purpose is raising and maintaining of the tank content temperature to enable an economic tank discharge during the cargo offloading(Gunner 2002; Chen 1996; Zhao et al. 2019).

The tank heating coils are traditionally executed as a grid of steam-driven parallel tubes, evenly distributed all over the tank bottom. Sometimes, when enlarged quantity of tubes is required, the heating coils are arranged on two levels, one above the other. It is interesting to note that this concept has remained unchanged since the advent of the world tanker fleet.

The early works of van der Heeden and Mulder (1965),Couchman et al. (1966), Saunders (1968), and Akagi(1969) set out the fundamentals of the tanker cargo heating design. These studies provided the model and fullscale measurement results, as well as the heat transfer coefficient correlations. An extensive experimental study(Suhara 1970; Kurihara et al. 1972) comprising model-tank measurements, as well as the real tanker on-board measurements, enlighten the subject of crude oil heating. Akagi and coworkers studied other kinds of highly viscous cargoes, such as low-grade fuels and coal-oil mixtures (Akagi et al. 1985). Also, Akagi and Kato (1987) and Akagi and Uchida (1987) studied the influence of tanker rolling on the heat transfer within the tank. These latter works are also important due to the first implementations of the modern computational techniques by the finite difference method.The heating simulations presented opened a possibility to understand better the complex fluid flow and heat transfer processes within the cargo tanks. Unfortunately, more recent research results are not found.

Contrary to the lack of marine applications, significant progress is achieved in the oil onshore storage field, where the cylindrical floating roof tanks have taken place. Zhao et al. (2017) numerically investigated a temperature distribution and its relationship with the flow pattern within a tank. Sun et al. (2018) performed simulations to analyze the heating effect of differently structured coils. Yang et al.(2018) conducted an experimental work that clarified the oil temperature fluctuation concerning the tank regions and variable ambient conditions.

Nowadays, tanker cargo heating seems out of focus,despite the significant changes that have occurred recently.Firstly, due to the evolved regulations, the tanker structure arrangements have changed considerably by abandoning the risky and thermally inefficient single-hull concept and introducing a safer and thermally more efficient double-hull one. According to the present tanker design, all structural elements (frames, girders, and stiffeners) are disposed of out of the tank. The consequence is that modern tanks are enclosed by plain and clean surfaces (see Figure 1), with no obstructions that interfere with the flow of the cargo within the tank. Secondly, the advanced computing technologies that have emerged enable massive numerical simulations that were not feasible in the past. These two changes make it possible to revisit the tanker cargo heating process (Pivac and Magazinović 2015) and suggest a fresh, unconventional design (Magazinović 2018, 2019a, b, 2020).

Figure 1 Tank cross-section: a problem scheme

The main outcome of Pivac and Magazinović (2015) is the discovery that heated cargo exhibits a powerful circular motion during the heating. This phenomenon permits a wholly new cargo heating concept based on utilizing the cargo circular motion for enhancing the coil heat transfer and obtaining a significant material and work-hour savings. This paper investigates the approach in more detail.

The paper is organized as follows. In Sect. 2, a brief description of the proposed heating coil approach is provided. Then, in Sect. 3, a detailed description of the computational fluid dynamics (CFD) simulation setups is given.The simulation results are provided and discussed in Sect. 4,wherein, in Sect. 4.3, the results evaluation by the alternative calculation procedures is provided. Finally, in Sect. 5, the conclusions of the study are summarized.

2 Multi‑level Heating Coil Bundle

The proposed multi-level heating coil bundle design is based on the following concepts:

Tube Concentration Contrary to the conventional heating coils arrangements, the proposed design concentrates the heating coils into a slim and multi-level bundle, wherein the level is defined as a unique distance between the heating tube centerline and the bottom of the tank.

Asymmetric Placement The heating coil bundle is laid horizontally, close above the tank bottom, parallel to the vessel’s longitudinal bulkhead, extended closer to the tank’s inner side wall than its outer side wall.

Large-scale Circulation After a sufficient heating duration,the heated cargo circulates around the axis that is parallel to the heating tube centerlines.

Horizontal Cross-Flow The heated cargo cross-flows through the void space between the bundle tubes in a nearly horizontal direction.

Superimposing Forced on Natural Convection Owing to the superposition of the circulation-driven forced convection on the buoyancy-driven natural convection, the heat transfer mechanism upgrades to the more efficient mixed convection.Clean, Compact Design The bundle arrangement features a small form factor, leaving the majority of the tank bottom free of the equipment or structural obstacles.

Simplified Cleaning, Survey, and Maintenance Free portions of the tank bottom are easy to clean when employing the crude oil washing system. Furthermore, the compact bundle simplifies periodic surveys, as well as the possible maintenance works.

Reduced Installation Workload The bundle features standard profile supports and two fittings only, requiring fewer work hours to install.

Figure 2 depicts a heating coil bundle satisfying the imposed design concepts. However, it should be noted that different embodiments are also possible.

Figure 2 Proposed multi-level heating coil bundle

The heating coil bundle is characterized by a number of serially leakproof joined straight and U-shaped heating tubes, providing a coil grid with a steam inlet on the bundle top, and a condensate discharge on the bundle bottom.Heating tubes are connected to a number of supports by using U-shaped bolts and nuts, making a bundle a compact structure extended along the tank bottom.

A heating steam, generated in the tanker engine room and distributed over the deck level by the header and manifold, is supplied by a downcomer to the bundle steam inlet. On the bundle discharge side, a condensate lift is used to ensure a condensate-only return to the deck level discharge manifold and the return header. Since the steam advances through the bundle in a top-down direction, no water hammer-related difficulties should occur.

When one heating coil bundle is not sufficient to fulfill the tank-heating requirements, two or more heating coil bundles are needed. In that case, the bundles are aligned in a row along the tank bottom length.

The remaining sections of the paper are devoted to a simulation-based evaluation of the proposed design. A comparison with the conventional design is also provided.

3 Simulation Models

Two simulation models are built for the study. The first one encompasses the conventional heating coil design and the second one deals with the proposed bundle design.

The simulation models are based on the actual 65 000 dwt double-hull oil products tanker (Pivac and Magazinović 2015), wherein the model-tank particulars comprise a 7360 m3capacity, 17.5 m breadth, 16.8 m height,26.4 m length, and 15.4 m filling level (Figure 1).

The conventional heating coils are executed in the form of three heating coil blocks, comprising eight straight 50A-size(60.5 mm outer diameter) steel tubes each, arranged at 400 mm transverse pitch, 150 mm above the tank bottom.The void spaces between the blocks are 2.45 m wide.

The proposed heating coil bundle comprises a 20-level arrangement of 50A-size straight steel tubes, with both the transverse and longitudinal pitches of 181 mm, wherein the down-most tube is situated 90 mm above the tank bottom(Figure 2). Three coil bundles, positioned 7.5 m apart from the tank inner side wall, are laid along the tank bottom.

Both simulation models are set as a two-dimensional unsteady heat transfer and fluid flow driven by the action of the buoyancy forces. The simulations are performed by using the finite volume method, as implemented in OpenFOAM 3.0 CFD toolbox (Greenshields 2015).

3.1 Governing Equations

Governing equations fully describe the physical state of any part of the analyzed fluid domain. For the unsteady compressible flow, presented in vector notation, a set of governing equations comprise a mass conservation equation:

whereρis the fluid density,tis the time,Uis the velocity vector,μeffis the effective viscosity,pis the static pressure,gis the gravitational acceleration vector,Kis the kinetic energy, andαeffis the effective thermal diffusivity.

By solving this system of equations, the pressure,enthalpy, and velocity vector components throughout the domain become available. Afterward, the remaining important parameters (e.g., temperature or heat transfer coeffi-cients) may be determined.

3.2 Domain Discretization

Two two-dimensional meshes are generated for the study. A mesh representing a conventional heating coil design comprises 209 382 cells, mostly hexahedra with 242 prisms,whereas the mesh devoted to the proposed heating coil bundle design comprises 182022 hexahedra and 264 prisms.

To determine the temperature gradients around the heating tubes accurately, coil boundary is meshed by 27 layers of cells, each layer comprising 120 cells, and the first layer thick 0.05 mm only. The tank enclosure is meshed by a fourlayer boundary. All cell face lengths are smaller than 60 mm.

3.3 Model Setup

Both simulation tasks are set to heat the high-viscosity fuel oil for 5 h at the typical environmental conditions of an air temperature of 2 °C and a sea temperature of 5 °C.

For simulation purposes, a 585 mm2/s nominal viscosity RMH 45 residual fuel oil was selected, with the thermal properties provided in Table 1. The fuel oil density, specific heat capacity, and thermal conductivity may be treated as linearly dependent on temperature. However, due to the high nonlinearity, in this study, the oil viscosity is approximated by a seventh-degree polynomial, as provided by Eq. (1) in Magazinović (2020). A heat flow model is assumed to be laminar.

Table 1 The RMH 45 (ISO 8217) residual fuel oil thermal properties used in the study

The initial fuel oil temperature is 55 °C, and the heating coil is driven by a 170.4 °C 8-bar saturated steam. A 165 °C maximum heating tube temperature is assumed. A 15 °C temperature difference between the tube cross-sectionupper-most and down-most circumferential points is assumed (Kurihara et al. 1972), resulting in a 157.5 °C mean heating coil temperature and the linear temperature distribution across the tube diameter. A schematic that further depicts this boundary condition has already been provided(see Figure 3 in Magazinović (2020)). The heating coils are additionally subjected to the cargo hydrostatic pressure and no-slip boundary conditions.

Figure 3 Isotherms and velocity vectors for the conventional heating coil design case (the cargo circulation is emerging)

The heat supplied by the heating coils is mostly used for cargo heating. However, a part of the energy is released to the environment due to the tank wall convective heat outflows. The tank bottom and deck heat transfer coefficients are assumed as 3.2 W/m2K, Jandrijević et al. (2007), while the tank outer wall heat transfer coefficient is assumed as 3.3 W/m2K, Jandrijević et al. (2007). The tank inner side wall is taken as thermally neutral, i.e., no heat transfer is assumed.

Tank walls are modeled by the no-slip boundary conditions and the cargo hydrostatic pressure, whereas the upper cargo boundary, actually subjected to the open atmosphere,is modeled by zero total pressure and the two-way flow free velocity definition.

3.4 Software Setup

For simulation purposes, abuoyantPimpleFoamsolver(Greenshields 2015) is selected. It is a segregated, pressurebased solver for compressible buoyancy-driven fluid flows that merges the PISO and SIMPLE algorithms (Moukalled et al. 2016). Since it is a transient solver, for time discretization, a Euler implicit method is used. For the gradients and Laplacian discretization, Gauss linear and Gauss linear-corrected schemes are applied, respectively, while a Gauss van-Leer interpolation method is selected for the convective term discretization.

The software setup comprises five PIMPLE iterations per time step, each iteration comprising two correction steps and two non-orthogonality correction steps. To solve the pressure equation, a PCG solver is used with the DIC preconditioner and the 10-8tolerance. For the momentum and energy equations, a PBiCG solver is used with the DILU preconditioner and the 10-6tolerance.

Residual control is governed by a 10-4absolute tolerance.All the iterations except the final ones are stabilized by the under-relaxation factors of 0.7 for the pressure and 0.3 for the velocity and enthalpy.

For the simulation-time advancement, variable-size time steps are used, governed by a maximum Courant number set to 0.5 throughout the simulations. At each time step,after determining the fluid temperature, the PIMPLE solver invokes a thermophysical module to update properties as needed.

4 Results

The results presented herein encompass two cargo heating simulations. The first simulation results, provided in Sect. 4.1, relate to the conventional heating coil design and establish a baseline for the comparison. The second simulation results, presented in Sect. 4.2, delineate the performance of the proposed multi-level heating coil bundle (see Figure 2). Both simulations start with the cargo at the rest condition and share the same boundary conditions and simulation parameters. The initial time step size is set to 10-4s.

Figure 4 Heat transfer coefficient for the conventional heating coil design case

4.1 Conventional Design

During the first few minutes of heating, each heating coil acts independently of each other. However, afterward, the eight plumes of each of the three heating coil blocks (see Figure 1) unite in a larger plume. Initially, the plumes move vertically upwards, generating the swirls throughout the lower part of the tank. Due to the continued input of the heat energy, the swirls gradually occupy the whole tank, causing the entire tank content to move. Although the fluid motion is initially chaotic, the later flow pattern gradually takes the form of a large-scale circulation(Krishnamurti and Howard 1981; Sreenivasan et al. 2002;Xi et al. 2006), as depicted in Figure 3. This phase of the tank fluid flow may be arbitrarily entitled as a precirculation phase. After around 2700 s of tank heating,the large-scale circulation is fully developed, denoting the start of the circulation phase of the tank fluid flow.

The fluid flow and heat transfer processes within the tank are rendered in more detail in Figures 4, 5, and 6.

Figure 5 Cargo velocity for the conventional heating coil design case

Figure 6 Cargo temperature for the conventional heating coil design case

Figure 4 shows a time variation of the heating coil surface area-averaged heat transfer coefficient. The area-averaged coefficient of coil surface heat transfer is defined by:

whereQcis the coil heat flux (determined offline by an OpenFOAM wallHeatFlux utility),Acis the coil area, andTcandTbare the coil surface and bulk oil temperatures,respectively.

During the pre-circulation phase, the coil heat transfer coefficienthcfluctuates between the initial 98.7 W/m2K and final 131.3 W/m2K, with the time-averaged value of 115.3 W/m2K. During the circulation phase, the heat transfer coefficient fluctuates around the time-averaged valuehc= 121.3 W/m2K (a 5.2% rise in comparison with the precirculation phase average).

A rising trend of the heat transfer coefficient may be attributed to the raising trends of the peak and average fluid velocities (see Figure 5) during the same time frame. The peak velocity is defined as the maximum velocity amplitude determined in any of the cells within the domain, whereas the average velocity represents the velocity magnitude averaged over all domain cells.

The cargo temperature variation by time is provided in Figure 6, where the full-lineweight line refers to an average cargo temperature of 25 mm above the tank bottom,and the dotted line renders an average cargo temperature at the tank bottom. The bulk cargo temperature steadily rises from the initial 55 °C to the final 56.8 °C, whereas the minimum cargo temperature at the tank bottom is 36.8 °C, att=11 020 s.

The convective heat loss through the tank boundary at the end of the simulation totalsQloss=164.4 kW, wherein the tank bottom heat outflow accounts for 41.5 kW.

4.2 Proposed Design

When the cargo large-scale circulation is concerned, the proposed coil bundle design case behaves similarly to the conventional heating coil design case. During the pre-circulation phase, the warm cargo plume moves upward, causing swirls in the upper tank zone (Figure 7). As the heating continues, the swirls become larger, gradually overtaking the whole tank. Afterward, a multiple of swirls gradually transforms into a single large-scale circulation, which results in a nearly horizontal cross-flow of the heated cargo through the void space between the bundle tubes (Figure 8).

Figure 7 Isotherms and velocity vectors for the proposed heating coil bundle design case (pre-circulation phase)

Figure 8 Isotherms and velocity vectors for the proposed heating coil bundle design case (circulation phase)

As in the conventional design case, the proposed design pre-circulation phase span is 2700 s, during which the bundle heat transfer coefficient, averaged over 20 heating coils, fluctuates around the average value of 147.4 W/m2K(Figure 9). Afterward, in the circulation phase, the bundle heat transfer coefficient fluctuates around an uprated average value ofhc=178.4 W/m2K (a 21.2% rise in comparison with the pre-circulation phase average). It should be noted that the high fluctuations presented in Figure 9 result from the flow pattern within the tank. Also, these fluctuations do not attenuate over time. The proposed design behaves significantly better than conventional designs.Such improvement is attributed to the enhanced fluid flow around the proposed bundle heating tubes. Large-scale circulation, which is responsible for the cross-flow, is mostly generated by the bundle in the asymmetric transverse position within the tank. The temperature difference between the outer and inner tank side walls further aids circulation.

Figure 9 Heat transfer coefficient for the proposed heating coil bundle design case

A graphical representation of the heated cargo peak and average velocity magnitudes is provided in Figure 10.During the pre-circulation phase, the peak velocity tops at 0.264 m/s and averages 0.189 m/s. In the same time frame, the average velocity tops at 0.076 m/s and averages 0.044 m/s. Compared with the conventional heating coil design case, the average peak velocity is 6.8% higher,while the average velocity is 24% lower. During the circulation phase, the peak velocity tops at 0.322 m/s and averages 0.231 m/s, 4.9% lower than the conventional design case average of 0.243 m/s. The average velocity tops at 0.095 m/s and averages 0.085 m/s, 10.5% lower than the conventional design case average of 0.095 m/s. The general fall of the velocity readings may be attributed to the heating coil bundle that opposes the cargo free flow.

The heating coil bundle divides the tank’s bottom part into two unequal regions: a larger inflow region, and a smaller outflow region (Figure 7). Whereas the flow pattern in the inflow region follows the behavior shown in the tank’s upper part, the flow pattern in the outflow region behaves slightly differently; a less-intensive auxiliary circulation arises with the opposite rotation. To depict the difference between the outflow and inflow regions, the oil velocity was calculated at two probes, positioned 5.825 m and 11.075 m off the tank’s inner side wall and 150 mm above the bottom of the tank. The velocity at the inflow region probe averaged 0.030 m/s and peaked at 0.101 m/s. The velocity at the outflow region probe averaged 0.012 m/s and peaked at 0.072 m/s.

Figure 10 Cargo velocity for the proposed heating coil bundle design case

Figure 11 Entrance cross-flow velocity determined at half of the bundle height

To quantify the heating coil bundle cross-flow velocity,magnitudes of the cargo flow velocity at three probe points are recorded and analyzed. The probe points are chosen at half of the bundle height, at the levels of the Entrance, Middle, and Exit points of 993, 1038, and 1083 mm, respectively,counted from right to left (Figure 8). While the Entrance and Exit points are aligned with the tube column centerlines, the Middle point is situated in-between. The velocity readings at the Entrance point are graphed in Figure 11, whereas the complete set of the readings is summarized in Table 2.

The dimensionless Richardson number,Ri=Gr/Re2,whereGrandReare the Grashof and Reynolds numbers,respectively, is a heat transfer regime characterization criterion. Namely,Ri>> 1 denotes a natural convection,Ri<< 1 represents a forced convection, andRi≈ 1 indicates a mixed convection. By using Table 2 data, it is found that the minimum and average Richardson numbers are 1.3 and 7.9, respectively. These values denote a mixed convention with the variable contribution of the forced convection. WhileRi=1.3 indicates a comparable impact,Ri=7.9 represents a dominant natural convection.

Table 2 Cross-flow velocity at half of the bundle height

A strong correlation is found between the peaks of the entrance cross-flow velocity (Figure 11) and the bundle heat transfer coefficient (Figure 9). When the entrance cross-flow velocity is at a local minimum, the heat transfer coefficient is also at a local minimum, and the high Richardson number indicates a natural convection. Alternatively, when the entrance cross-flow velocity is at a local maximum (the low Richardson number denotes a significant forced convection component), the heat transfer coefficient is also at a local maximum.

A time variation of the cargo temperature is provided in Figure 12. At the tank bottom, the average temperature minimum, attained att=17,300 s, is 34.7 °C, 2.1 °C lower than in the case of the conventional coil design. This temperature indicates a slightly inferior behavior regarding the possibility of the cargo components settling and solidification. However, as heating proceeds, temperature eventually rises. During the 5-h heating, the bulk cargo temperature averaged 25 mm above the tank bottom, steadily rising from the initial 55 °C to the final 57.1 °C. The temperature rise of 2.1 °C is achieved by 20 heating tubes. For the reference, in the conventional heating coil design case, a 1.8 °C temperature rise is attained by 24 heating tubes.

Figure 12 Cargo temperature for the proposed heating coil bundle design case

This study has revealed that intensive fluid mixing occurs within the tank. Calculations show that the fluid temperature in any part of the domain, except the boundary layers, differs by less than 0.4 °C.

After heating for 5 h, the heat loss through the tank bottom is equal to 41.5 kW, and the tank total convective heat outflow reachesQloss=163.8 kW. Both results are comparable with the conventional heating coil design case values. The proposed and conventional designs behave almost identically, since the oil-flow characteristics on the outer tank boundary are virtually unchanged.

4.3 Results Evaluation

The conventional coil heat transfer coefficient results, as outlined in Sect. 4.1, are evaluated by employing Akagi’s classic equation (Akagi 1969):

wherekis the cargo thermal conductivity,dis the outer coil diameter,Rais the Rayleigh number, andμandμcare the cargo dynamic viscosities determined at bulk cargo and coil surface temperatures, respectively.

By using the cargo data of Table 1, Eq. (5) predicts a natural convection heat transfer coefficient of 116.2 W/m2K. This value is comparable with the pre-circulation phase time-average of 115.3 W/m2K (a-0.77% difference). It is important to note that the circulation phase time-average heat transfer coefficient of 121.3 W/m2K should not be evaluated by the Akagi equation since the latter is based on the natural convection heat transfer mechanism only.

The proposed heating coil bundle results for the heat transfer coefficient, as presented in Sect. 4.2, are evaluated by employing the Gnielinski approach (Gnielinski 2010).The procedure of Gnielinski is based on the forced convection heat transfer mechanism, since the Nusselt number is defined as a function of the coil bundle geometry and Reynolds and Prandtl numbers. For the Reynolds number calculation, the average cross-flow velocityUcfand streamed tube lengthlare relevant:

whereUentandUextare the entrance and exit cross-flow velocities, respectively, as provided in Table 2.

By using data from Table 2, the two characteristic values of the heat transfer coefficient are determined and provided in Table 3. The results reveal, besides a comparable agreement with the CFD results, a strong relationship between the cross-flow velocity and the bundle heat transfer coefficient.Furthermore, the cargo cross-flow velocity is proven to be the most important parameter in determining the coil bundle overall heat output. However, it is important to note that the pre-circulation phase of the proposed bundle heating shouldapproximation. However, since the Boussinesq approximation neglects the dynamic viscosity and thermal conductivity changes with temperature, significant errors may be introduced. For example, Bazdidi-Tehrani et al. (2018) reported deviations of up to 33% and 45% in Nusselt number’s assessment. Therefore, a more demanding and general compressible formulation is retained herein.

Table 3 Comparison of the circulation phase heat transfer coefficient determined by this study and the procedure of Gnielinski (2010)

Table 4 Comparison of the required heating coil area

Initially, both the laminar and the turbulent heat flow models were considered for the large-scale circulation phase simulation. Since the RNG k-epsilon turbulence model grossly overestimated the heat transfer coefficient values provided in Table 3, a more conservative laminar flow model is adopted in the present study.not be evaluated by the Gnielinski method, since the initial fluid flow is in the vertical direction (Figure 7).

4.4 Required Heating Coil Area

The required heating coil areaAcmay be determined by iteration from the energy balance equation (Magazinović 1987):

whereT1andT2are the cargo initial and final temperatures, respectively,this the heating duration,mis the cargo mass, andcpis the cargo-specific heat capacity at constant pressure.

For the cargo 4-day heating from 44 to 66 °C temperature,the required heating coil area calculation results are provided in Table 4. To achieve these results, the average heat transfer coefficientshc, determined in Sections 4.1 and 4.2, are used in Eq. (9).

5 Discussion

To check the results mesh-size independence, a procedure recommended by Celik et al. (2008) is applied.

Two coarser meshes, measuring 112965 and 65703 cells,are generated and tested. The corresponding circulationphase average heat transfer coefficients are 176.4 W/m2K and 182.1 W/m2K, respectively. Under the apparent orderp=3.99, the following error estimates are recorded: an approximate relative error of 1.1%, an extrapolated relative error of 0.7%, and a fine-grid convergence index of 0.9%.

The calculations presented are characterized by an excessive simulation time, primarily due to a compressible,pressure-based problem formulation. Significant simulationtime reductions may be achieved by applying the Boussinesq

6 Conclusions

In this paper, a novel heating coil bundle with the tubes arranged in a multi-level manner is proposed and analyzed.The bundle is characterized by a compact, small form-factor design that occupies a minimal tank bottom area. In addition, two fittings per bundle ensure an improved installation process.

The bundle generates a heated cargo large-scale circulation that enables a superposition of the circulation-driven forced convection on the buoyancy-driven natural convection, providing a more efficient mixed convection heat transfer mechanism.

Performed numerical simulations have shown that in the case of an RMH 45 residual fuel oil heating by an 8-bar steam, a 47.1% higher average heat transfer coefficient may be achieved, allowing a 32.0% reduction of the required heating coil area.