时间:2025-01-07
Ying Yang,Haiyong Ao,Yugang Wang,Wentao Lin,Shengbing Yang,Shuhong Zhang,Zhifeng Yu and Tingting Tang
Cytocompatibility with osteogenic cells and enhanced in vivo anti-infection potential of quaternized chitosan-loaded titania nanotubes
Ying Yang,Haiyong Ao,Yugang Wang,Wentao Lin,Shengbing Yang,Shuhong Zhang,Zhifeng Yu and Tingting Tang
Infection is one of the major causes of failure of orthopedic implants.Our previous study demonstrated that nanotube modi f i cation of the implant surface,together with nanotubes loaded with quaternized chitosan (hydroxypropyltrimethyl ammonium chloride chitosan,HACC),could effectively inhibit bacterial adherence and bio f i lm formation in vitro.Therefore,the aim of this study was to further investigate the in vitro cytocompatibility with osteogenic cells and the in vivo anti-infection activity of titanium implants with HACC-loaded nanotubes(NT-H).The titanium implant(Ti),nanotubes without polymer loading(NT),and nanotubes loaded with chitosan(NT-C)were fabricated and served as controls.Firstly,we evaluated the cytocompatibility of these specimens with human bone marrow-derived mesenchymal stem cells in vitro. The observation of cell attachment,proliferation,spreading,and viability in vitro showed that NT-H has improved osteogenic activity compared with Ti and NT-C.A prophylaxis rat model with implantation in the femoral medullary cavity and inoculation with methicillin-resistant Staphylococcus aureus was established and evaluated by radiographical,microbiological,and histopathological assessments.Our in vivo study demonstrated that NT-H coatings exhibited signi f i cant anti-infection capability compared with the Ti and NT-C groups.In conclusion,HACC-loaded nanotubes fabricated on a titanium substrate show good compatibility with osteogenic cells and enhanced anti-infection ability in vivo,providing a good foundation for clinical application to combat orthopedic implant-associated infections.
Titanium-based intramedullary nails have been widely used in the treatment of both closed and open tibial and femoral fractures;however,infections may occur,especially in the contaminated tibia and femur fractures.1–2In a large series of tibial shaft fractures treated by intramedullary nailing,there was an incidence of postoperative infection of 1.9%for closed fractures and 7.7% for open fractures out of 1 106 cases.3To remedy such an implant-associated infection,systemic administration of antibiotics and removal of intramedullary nails are the two conventional approaches,which may compromise patient compliance and lead to systemic toxicity, osteomyelitis,and bone nonunion.4Thus,it is of great signi f i cance to endow the implants with anti-infection properties when the fracture f i xation is at high risk of infection.
As an innovative modi f i cation of titanium implants, titania nanotube(TNT)arrays generated over a Ti surface by a simple and adjustable electrochemical anodization process5have been extensively explored as a new antibiotic-loading method to mitigate the side-effects of systemic drug administration.6–7Meanwhile, the nano-featured surface topography itself possesses improved antibacterial potential and osteoblastic activity.8–11The most common microorganisms correlatedwith implant-associated infection are Staphylococcus aureus and Staphylococcus epidermidis,which can adhere to implant surfaces and form bio f i lms.12Our previous in vitro and in vivo studies revealed that gentamicin-loaded nanotubes on titanium substrates exhibited evident antibacterial activity for the two bacterial strains mentioned above.13–14However,the resistance to β-lactamase,aminoglycoside,lincosamide,trimethoprim, macrolide,tetracycline,and sulfonamide antibiotics in S.aureus and S.epidermidis is widespread in current orthopedics surgery.15–16Therefore,implants with good antibacterial capability,especially under methicillinresistant stapthylococci infection,is critical to the successful f i xation and healing of bone fractures in current orthopedic surgery.
As a new water-soluble chitosan derivative,quaternized chitosan emerged to address the poor water solubility and restricted antibacterial capability of chitosan under an alkaline environment.17–19As a cationic antimicrobial agent,quaternized chitosan has a broad spectrum of antibacterial activity caused by the electrostatic interaction between the positively charged quaternary ammonium groups of hydroxypropyltrimethyl ammonium chloride chitosan(HACC)and the negatively charged phosphoryl groups of the phospholipid components of bacteria membranes,which affected the cytoplasmic membrane integrity,eventually leading to cell death.20–21In our previous reports,HACC-loaded polymethylmethacrylate exhibited obviously inhibited bio f i lm formation by antibiotic-resistant staphylococci both in vitro and in vivo.22–23However,polymethylmethacrylate bone cement is not suited to intramedullary f i xation of bone fractures.Thus,we further fabricated HACC-loaded nanotubes with various diameters on titania implants,which exhibited effectively inhibited bacterial adherence and bio f i lm formation in vitro.24
Although the in vitro antibacterial activity of HACC-loaded nanotubes with a diameter of 200 nm was reported to be better than those with a diameter of 160 nm,24the cytocompatibility had a negative correlation with the diameter of the nanotubes.13Therefore,we fabricated TNTs with 160 nm diameters on titanium plates and rods for the consideration of both the antibacterial capability and cytocompatibility in this study.Quaternized chitosan with a degree of substitution of 26%was loaded into these nanotubes to form an effective local antibiotic delivery system,and the in vitro cytocompatibility was assessed. Then,a methicillin-resistant S aureus strain was selected to establish an intramedullary infection model in rats and the in vivo anti-infection properties of the HACC-loaded TNTs coating were systematically evaluated.Meanwhile, titanium without modi f i cation(Ti),TNTs without drug loading (NT),and chitosan-loaded titania nanotubes(NT-C)were also evaluated and compared.
Preparation of drug-loaded TNTs
TNTs with diameters of 160 nm were manufactured on Ti plates(10 mm in diameter and 2 mm thick)and rods (15 mm in length and 2 mm in diameter)at a constant voltage of 70 V for 1 h by electrochemical anodization treatment according to our previous reports.13,24Chitosan (MW=50 000,87%N-deacetylation)was purchased from Zhejiang Yuhuan Ocean Biochemistry Co.,Ltd(Yuhuan, Zhejiang,China).Glycidyl trimethylammonium chloride (MW=151.63 g·mol-1)was purchased from Sigma-Aldrich (St.Louis,MO).Other chemicals used were of analytical grade.HACC with a quaternary ammonium degree of substitution of 26%and molecular weight of 5.0×104was prepared by combining chitosan and glycidyl trimethylammonium chloride,as reported in our previous work.22Then,chitosan and HACC solutions of 20 mg·mL-1dissolved in deionized water were loaded into the TNTs by lyophilization method and vacuum drying.7In brief,5 μL volume of drug solution was pipetted onto the surface of the nanotube,and then gently spread to ensure even coverage.The drug-loaded specimens were dried under vacuum in a freeze-drying system(Labconco 7753072; Labconco Corp,Kansas City,MO)at-45°C for 2 h.The loading step was repeated for approximately 20 cycles until the nanotubes were loaded with 2 mg of chitosan and HACC according to our previous study.24All prepared samples were sterilized with 25 kGy of60Co irradiation before performing the in vitro and in vivo experiments.
Characterization
Scanning electron microscopy(SEM,HITACHI SU8220, Tokyo,Japan)was used to verify the surface morphologies of the specimens.The surface wettability of the samples was determined by measuring the static water contact angles using the sessile drop method on a drop-shape analysis system(JC-2000D3,Shanghai Zhongcheng Digital Technology Co.,Shanghai,China)at ambient temperature and humidity.Meanwhile,images were collected by the camera.Three measurements were performed at different points on each sample.
Preparation of bacteria
Methicillin-resistant S.aureus(ATCC43300)was purchased in a freeze-dried form from the American Type Culture Collection(Manassas,VA).This strain was a bio f i lmproducing bacterial strain as veri f i ed by our previous study.22Cells were suspended in phosphate-buffered saline(PBS)solution to 1×105CFUs·mL-1after overnighttrypticase soy broth culture.The minimal inhibitory concentrations of chitosan and 26%HACC against ATCC43300 were previously reported to be 64 μg·mL-1and greater than 1 024 μg·mL-1,respectively.22
In vitro cytocompatibility evaluation
Human mesenchymal stem cells,isolated and expanded as previously described,25were selected to evaluate the cytocompatibility of these samples in vitro.A cell counting kit-8(CCK-8)assay was used to analyze cell attachment at 4,8,and 12 h.The cells were seeded into wells containing the specimens at a density of 4.0×104per cm2,and empty wells containing α-MEM and specimens served as blank controls.At each time point,a total of 50 μL of CCK-8 solution(Dojindo Molecular Technologies Inc.,Kumamoto, Japan)was added to each well and then incubated for 3 h before reading at 450 nm,with 620 nm as the reference wavelength.The mean absorbance value(optical density) obtained from the blank control was subtracted from the optical densities of the tested groups.Meanwhile,the cells on the discs were also stained with 4,6-diamidino-2-phenylindole(Molecular Probe,Sigma Aldrich,St.Louis, MO,USA)for 15 min to observe the cell adhesion using a fl uorescence microscope(Leica AF 6000,Heideberg, Germany).
Similar to the cell adhesion test,cell proliferation was also evaluated by the CCK-8 assay after 1,4,and 7 days,and the seeding density of the cells was 2.0×104per cm2.The modi f i ed optical density values at 4 and 7 were normalized to those at day 1 in terms of the number of attached cells grown on different samples at day 1.26The cell spreading and morphology on the discs were visualized by confocal laser scanning microscope(CLSM)(Leica TCS SP8,Leica Microsystems,Wetzlar,Germany),and the cell seeding procedures were similar to those of the cell attachment test.After 24 h of incubation,the samples were f i xed with 4.0%paraformaldehyde for 15 min,and then the cells were permeabilized with 0.1%Triton X-100 in PBS for 10 min.After washing three times with PBS,the f i lamentous actin of the cell cytoskeleton was stained with rhodamine-phalloidin (Biotium,Hayward,CA)for 45 min,and then the nuclei were stained with 4,6-diamidino-2-phenylindole for 15 min.
In addition,the cell viability of various specimens was analyzed by a Live/Dead Cell kit(ab115347,Abcam, Cambridge,UK)as described previously.27The cell seeding procedures were similar to those of the cell spreading assay. After a 24-h co-culture,cells attached on the specimens were stained with 500 μL of combination dye for 10 min,and were then detected by the CLSM(Leica TCS SP8).The viable cells with esterase activity appeared green,whereas dead cells with compromised plasma membranes appeared red, as described in the manufacturer’s protocol.
Implant infection model in rats
The in vivo experimental procedures were approved and performed in accordance with the guidelines of the Animal Ethics Committee of Shanghai Ninth People’s Hospital.Forty-f i ve speci f i ed pathogen-free grade 8-weekold male Sprague-Dawley rats(weighing 399.07±20.73 g) were randomly assigned to three independent groups (n=15 for each group).According to the previously reported surgical procedures,14,28–29the left knee was exposed through a middle parapatellar incision after general anesthesia with an intraperitoneal injection of 1% pentobarbital sodium(100 mg·kg-1body weight).The femoral medullary cavity was widened gradually with Kirschner rods to a diameter of 2.0 mm after the dislocation of the patellar.Then,50 μL of PBS containing ATCC43300 at a concentration of 1×105CFUs·mL-1was injected into the medullary cavity using a micropipette. Subsequently,a prepared Ti,NT-C,or NT-H rod was inserted. The opening cavity was sealed with bone wax,and then the surgical site was closed layer by layer.The rats were kept separate and allowed to eat and drink ad libitum. Fluorescence labeling was used to investigate new bone formation around the implants according to the established protocol.30In brief,calcein green(20 mg·kg-1body weight;Sigma-Aldrich)was injected subcutaneously at day 3 before sacri f i ce.The animals were killed after 42 days.No antibiotic was administered post-surgery.
Clinical evaluation
All animals in the three groups were observed and recorded on the day of surgery and 3,7,14,21,28,35, and 42 days after surgery.Body weight and temperature were selected as the observational indices and were obtained from all 15 animals in each group.14,23Weight was measured on a precision scale(TCS,Shanghai,China), and body temperature was determined by a veterinary digital infrared thermometer(HRQ-S60,Zhengzhou,China). Knee joint swelling,skin exudation,and other in f l ammatory signs were regarded as the main local signs of infection.
Radiographic evaluation
Lateral radiographs of the femur and knee joint were obtained at 3,21,and 42 days after implantation. Radiographic manifestations were assessed on the basis of a modi f i ed scoring system.23,31X-rays of the femurs and knee joints in all groups were read and interpreted in a blind manner by a radiologist unaware of the grouping characteristics and inoculum.Femurs were harvested and evaluated using a high-resolution micro-CT(SCANCO MEDICAL,μCT 80,CH-8306,Brüttisellen,Switzerland)at an isometric resolution of 20 μm(70 kV and 130 μA radiation source with 0.5 mm aluminum f i lter).Three-dimensionalhigh-resolution reconstruction images obtained from the overall,longitudinal and transverse sections,the bone volume/total volume and the cortical bone mineral density of rat femurs were analyzed by the software(Image Processing Language,v4.29d,Scanco Medical AG, Brüttisellen,Switzerland)provided by the manufacturer.
Microbiological assessment
Six rods in each group were aseptically explanted and rolled over trypticase soy agar for semi-quanti f i cation of bacteria adhesion on the rods on the day of sacri f i ce. The rods were placed in 5 mL PBS and then sonicated in an ultrasonic bath at 150 W(B3500S-MT,Shanghai,China)at a frequency of 50 Hz for 5 min,followed by rapid vortex mixing(Vortex Genie 2,Scienti f i c Industries,New York,NY) at maximum power for 1 min to thoroughly dislodge the adhered bacteria.14,29The adhered bacteria in the collected solutions after ultrasonication were measured by the spread plate method as previously reported.13Then,the femurs after explantation were quickly frozen in liquid nitrogen and ground to a powder under sterile conditions.23,29The bone powder was homogeneously vortexed in 5 mL PBS for 2 min.After centrifuging at 10 000 r·min-1for 20 s,50 μL of the supernatant was drawn and serially diluted 10-fold.The bacteria quantity in the bone powder was analyzed and expressed relative to the femur weight(CFUs·g-1femur)using the spread plate method.CLSM and SEM were used for direct observation of bio f i lm formation on different rods after explantation. The rods were stained with 500 μL of combination dye (LIVE/DEAD BacLight Viability Kits,L7012;Thermo Fisher Scienti f i c,Waltham,MA)and visualized by CLSM. Live bacteria with intact cell membranes appeared fl uorescent green,whereas dead bacteria with damaged cell membranes appeared fl uorescent red.Threedimensional images were acquired from random rod positions.Meanwhile,the explanted rods were dehydrated by a series of graded ethanol solutions(30%,50%,70%,80%, 90%,and 100%)for 10 min each.Subsequently,the rods were examined using SEM after critical-point drying and gold sputter-coating.
Histopathological analysis
The remaining three femurs without implants of each group were f i xed in 4%buffered formaldehyde for 2 days and decalci f i ed for 1 week using Rapidly Decalci f i er (DeCa DX-1000;Pro-Cure Medical Technology Co Ltd, Kwun Tong,Hong Kong)and then embedded in paraf f i n and cut using a microtome(CUT 6062;SLEE Medical,Mainz, Germany)to obtain 5-μm longitudinal and transverse sections.Hematoxylin and eosin and Masson’s trichrome staining were used to assess morphology,and Giemsa staining was used to assess bacterial contamination. Meanwhile,three undecalci f i ed femurs containing rods were embedded in methyl methacrylate for in f i ltration and polymerization after f i xation and graded dehydration. The embedded specimens were transversely cut at the middle and condyle of the femur(Leica SP1600 cutting equipment,Germany).The cut surface was glued to a slide,and sections were ground to a thickness of approximately 50 μm.The undecalci f i ed sections were stained with Van Gieson to observe the morphology of the cortical bone and osteointegration around the implants.Slices labeled with f l uorochrome were used to observe the new bone formation around the implants.Images were captured on a Leica DMI4000B(Leica Microsystems,Wetzlar, Germany).
Statistical analysis
The data were expressed as the mean±standard deviations(mean±SD).All in vitro experiments were repeated three times.One-way analysis of variance and the least signi f i cant difference test were used to evaluate the body weights,temperatures,and CFUs from the microbiological evaluations among the three independent groups. Nonparametric tests(the Mann-Whitney U test)were performed for comparison of the surface characteristics, in vitro cytocompatibility,and the radiographic evaluations among different groups.P<0.05 was de f i ned as statistically signi f i cant,and P<0.01 was considered highly statistically signi f i cant.All statistical analyses of the data were performed using SPSS software(v19.0,IBM Corp, Armonk,NY).
Surface characterization
The surface morphologies of Ti,NT,NT-C,and NT-H are shown in Figure 1.The diameter of the nanotubes was 160 nm,and the surfaces of the drug-loaded specimens retained the nanotubular structure as described above.
Figure 1 and Table 1 show the water contact angles of the four different specimens,which were 95.9±9.2°, 20.7±4.0°,81.3±3.7°,and 7.6±0.8°,corresponding to Ti, NT,NT-C,and NT-H,respectively.These results indicate that the hydrophilicity of NT and NT-H was signi f i cantly improved compared with Ti and NT-C(P<0.01).Meanwhile,the hydrophilicity of Ti was also lower than NT-C(P<0.05). Table 1 shows the surface energy and adhesion work of these specimens.The surface energies of NT (65.6±5.8 J·m-2)and NT-H(72.4±1.1 J·m-2)were signi f icantly higher than Ti(25.9±5.7 J·m-2)and NT-C (35.5±2.5 J·m-2)(P<0.01),and the adhesion work of NT (133.3±7.2 ΔE)and NT-H(144.9±1.2 ΔE)was signi f i cantly higher than Ti(66.8±11.8 ΔE)and NT-C(84.5±5.8 ΔE)(P<0.01),which is consistent with the results of the hydrophilicity evaluation.
Table 1.Contact angles,surface energy,and adhesion work of the four different samples
In vitro cytocompatibility evaluation
The results of the in vitro cytocompatibility evaluation are shown in Figures 2 and 3.As shown in Figure 2a,the counts of adhered cells on the surfaces of the NT was signi f i cantly higher than on the Ti at 4 h(P<0.05),and it could be observed that the cells adhesion on NT was better than the other groups at 8 and 12 h(P<0.01).Meanwhile,a lower counts of adhered cells was found on NT-C than on NT-H at 8 h(P<0.05).The cell proliferation measured by a CCK-8 kit on different samples is shown in Figure 2b and indicated that the cells on NT exhibited a higher relative proliferation rate than those on Ti and NT-C at 4 days(P<0.01). The relative proliferation rate of cells on NT-H was also higher than that on Ti(P<0.01)and NT-C(P<0.05)at 4 days.Moreover,the cell proliferation rate on Ti was lower than that on NT at 7 days(P<0.05)and no signi f i cant difference was found among NT and NT-H at the three time points(P>0.05).The numbers of cells stained with 4,6-diamidino-2-phenylindole on the surfaces of various specimens after 4,8,and 12 h incubation,which is consistent with the results described previously,is shown in Figure 2c.
The cytoskeletons of the human mesenchymal stem cells on the surface of various specimens at 24-h incubation are shown in Figure 3a.Cells grown on NT and NT-H displayed polygonal,multilayer,clustering,and confl uent morphology with more actin fi laments linking adjacent cells,whereas the cells on Ti and NT-C had spindle,spherical,monolayer,and dispersive morphology with fewer actin f i laments and poor spreading.The results indicated that cells on NT and NT-H showed well spreading compared with Ti and NT-C.In addition,acomparison of the cell viability of various specimens was performed by the Live/Dead Cell assay.As demonstrated in Figure 3b,the human mesenchymal stem cells displayed good cell viability in all four groups,with only a small number of dead cells detected in the NT-C and NT-H,which may be related to the slight cytotoxicity of the chitosan and HACC.Meanwhile,the cell con f l uence on the NT and NT-H was signi f i cantly better than the other two groups,which was consistent with the results analyzed above.
In vivo anti-infection potential
Clinical manifestations.There were no deaths or severe systemic complications during the 42-day follow-upperiod after implantation.Five rats in the Ti group and four rats in the NT-C group showed clear local clinical signs of infection around the surgical sites post-surgery; however,the animals in the NT-H group exhibited no evident exudation or suppuration.The body weights of all animals increased gradually,and the body temperatures of all animals remained consistent and normal. There were no signi f i cant changes in the body weights and temperatures among the three groups (P>0.05).
Radiographical evaluation.The radiographic signs of obvious osteolysis,periosteal reaction,and articular surface destruction around the distal femurs in all animals of the Ti and NT-C groups were observed using X-ray 21 days post-implantation.The X-ray images obtained from the animals with NT-H rods did not exhibit obvious signs of articular surface destruction,osteolysis,or periosteal reaction(Figure 4a).Micro-CT analysis was used to con f i rm the radiographic appearance on the day of sacri f i ce(Figure 4b),and showed obvious implant loosening and porous changes in the femoral cortical bone in the Ti and NT-C groups,whereas better bone-implant contact and cortical integrity were observed in the NT-H group.
The quantitative analysis of the X-ray images in Figure 4c showed that the radiographic scores increased gradually after surgery for the Ti and NT-C groups,whereas the scores slightly increased at 21 days and then gradually decreased at 42 days in the NT-H group.The Ti and NT-C groups had signi f i cantly higher mean scores than the NT-H group(P<0.01)at 21 and 42 days after surgery,and the NT-C group exhibited lower mean scores than the Ti group at the time of sacri f i ce(P<0.05).In addition,the bone volume/total volume(Figure 4d)and bone mineral density (Figure 4e)of the NT-H group were signi f i cantly higher than those of the other two groups(P<0.01).
Microbiological assessment.The rollover cultures of bacteria colonies that detached from the rods are shown in Figure 5a,indicating the lowest bacterial burden found in the NT-H rods among the three tested implants.In addition,the bio f i lm formation on the surface of different rods was observed directly by CLSM(Figure 5b).An obviously dense green f l uorescence,indicating bio f i lm formation,was observed on the surfaces of the Ti and NTC rods,with denser green f l uorescence observed on the Ti rods.Conversely,considerably less green f l uorescence and more discontinuous scattered red f l uorescence was observed on the NT-H rods.
After sonication of the rolled implants,the results of the plate spreading demonstrated that the cultures obtained from the NT-H rods(1.07×104±1.60×103CFUs per implant)had the lowest bacterial burden compared with the Ti(4.7×105±8.0×104CFUs per implant)and NT-C (2.83×105±3.06×104CFUs per implant)(P<0.01),and the mean colony counts for the NT-C rods were also obviously lower than those for the Ti(P<0.01)(Figure 5c). The bacterial burden per gram of femur also followed the trend of Ti group>NT-C group>NT-H group(Figure 5d), and the lowest bacterial burden was obtained in the NT-H group(1.22×104±9.88×102CFUs·g-1)compared withthe Ti(4.91×105±9.89×104CFUs·g-1)and NT-C (2.9×105±4.7×103CFUs·g-1)groups(P<0.01).The NT-C group also exhibited signi f i cantly lower CFUs/femur than did the Ti group(P<0.01).
Moreover,the SEM observation of the explanted rods further con f i rmed the results mentioned above(Figure 6); few scattered colonies and good spreading of osteoblasts were found on the surfaces of the NT-H rods. However,dense bio f i lm formation was found on the surfaces of the rods in the Ti and NT-C groups,especially in the Ti group,and the bio f i lm formation on the surfaces of the NT-C rods was separated discontinuously due to the nanofeatured surface topographies.The nanotubular structure of the titanium rods in the NT-C and NT-H groups remained unbroken after implantation,which con f i rmed the stability and feasibility of the drug-loaded nanotube structure in vivo. Histopathological evaluation.The morphological changes in the longitudinal decalci fi ed slices are assessed by hematoxylin and eosin and Masson’s trichrome staining,and the bacterial residue was confi rmed by Giemsa staining.As presented in Figure 7, obvious signs of massive destruction of cortical bone, accompanied by intracortical abscesses and in fl ammatory cell in fi ltration,medullary sequestrum formation and fi brosis were found in the Ti and NT-C groups,and lots of bacteria,especially in the Ti group,were observed in the intramedullary cavities,as shown in the Giemsa slices at high magni fi cation.In contrast,no evident abscess formation and signi fi cantly lightened bone destruction were observed in the NT-H group,and the number of bacteria colonized in the bone tissues decreased dramatically.
The morphological changes in the cortical bone and osteointegration around the implants on the transverse undecalci f i ed sections stained with Van Gieson are shown in Figure 8.There was obvious destruction of cortical bone in the Ti and NT-C groups,especially the expanded and thinner cortical bone in the Ti group.In contrast,the implants in the NT-H group were directly in contact with the surrounding bone with no obvious signs of cortical bone destruction,which is in accordance with the histopathological changes in the decalci f i ed sections analyzed above.In addition,there was obviously better osteointegration and new bone formation around the NT-H implants at the femoral condyle than in the other two groups,which furthercon f i rmed the in vivo cytocompatibility of the HACC-loaded TNTs.
The development of implant-associated infection is one of the most devastating complications in fracture f i xation surgery,and it sometimes results in poor osteointegration, chronic osteomyelitis,and f i nally implant failure.Furthermore,implant removal and multiple debridements are often necessary,which results in an unacceptable economic and psychological burden for both physician and patient.32
Implant surfaces favor bacterial adhesion,colonization, and bio f i lm formation after implantation,and the dose of contaminating colonies required to cause infection is low when the surgical site contains foreign material,according to several reported experimental models.33–34Furthermore, there is an immuno-incompetent f i bro-in f l ammatory zone in the interstitial milieu around the implants,which is susceptible to bacterial colonization and favorable to the recurrence of infection.35–36After the initial adhesion of bacteria to implant surfaces during a post-implantation period of 4–6 h,cell aggregation and accumulation occur to form a mature bio f i lm,which exhibits enhanced antibiotics resistance and increased protection from thehost defense.15,37Therefore,bacterial adhesion inhibition is of great importance to the manufacture of anti-infection implants.
The surface characteristics of biomaterials have been supposed to be important to bacteria and cell adhesion during the“race to the surface”competition.Hydrophobicity plays a critical role in a wide range of bacterial infection.38Hydrophobic surfaces exhibit a trend of bacterial adhesion due to nonspeci f i c adsorption of proteins and hydrophobic-hydrophobic interactions with bacterial surfaces,and it is supposed that reduced interaction between bacteria and a hydrophobic matrix could be achieved by increasing surface hydrophilicity.39–41Our results revealed that the hydrophilicity of NT and NT-H was signi f i cantly improved compared with Ti,which indicates that the nanotube structure formed on the titanium substrate increased the hydrophilicity of the surfaces.Meanwhile,the relatively high hydrophobicity observed on the NT-C surfaces may be caused by the poor water solubility of chitosan. Accordingly,the surface energy and adhesion work of NT and NT-H are also signi f i cantly higher than Ti and NT-C,which is believed to be meaningful to bacterial adhesion inhibition, as previously reported.42Meanwhile,our in vitro cytocompatibility assessments revealed that NT and NT-H displayed good osteogenic activity when compared with Ti and NT-C, which indicates that the vitality of human mesenchymal stem cells is not obviously affected by the loaded HACC and high hydrophilicity may be bene f i cial to the attachment of osteogenic cells.
However,there are opposite conclusions in regard to the relationship between the surface chemistry of the biomaterial and its antibacterial properties,which showed a positive correlation between the hydrophilicity and bacterial adherence.43–44Therefore,it is important to evaluate the in vivo antibacterial properties of the nanotube structure and the drug-loaded TNTs.Our in vivo results demonstrated that the chitosan-loaded TNTs showed obvious development of bone infection,which indicates that both the nanotubestructure and surface characteristics exhibited limited in vivo antibacterial activity over the course of 6 weeks post-surgery. The NT-H group showed good implant-bone contact, cortical integrity and dramatically decreased bacterial load; however,evident bone destruction and bacterial burden were observed in the Ti and NT-C groups.Although the in vitro antibacterial activity of the chitosan-immobilized titanium surface was investigated and veri f i ed by a previous report,45our present study indicated that it was still insuf f i cient to prevent the development of bone destruction due to the aggravated implant-associated infection in vivo when compared with NT-H.Various modi f i cations were utilized to improve the antibacterial activity of chitosan.46–47Our previous work also found that the nanotube arrays generated on the implants exhibited alleviated bone infection in vivo,which was similar to the antimicrobial performance of the NT-C in this study.14Therefore,it was necessary to use the HACC-loaded nanotube structure to prevent the development of bone infection in vivo.Although the hydrophilic interfaces of the biomaterials played positive roles in the bacterial adherence and bio f i lm formation inhibition in this study,the in vivo anti-infection potential of the implants depends on the antibacterial agents loaded in the nanotubes.In addition,the bacteria inoculation (1×105CFUs)in the medullary cavity of the distal femur in this animal model was much higher than the clinical amount of contaminating bacteria in the surgical site of the implantation,23which may be an important cause of the residual bacteria detected in the NT-H group.According to our previous in vitro research,the total amounts of HACC released from nanotubes with a diameter of 160 nm over 60 h was 1 080 μg,24which was above the minimal inhibitory concentration of the tested strain(64μg·mL-1).Thus, additional systemic antibiotic administration may be necessary to completely eradicate the bacteria,and modi f i cation of diameter of nanotubes,which can regulate the drug-loading,is a feasible and effective method to optimize the in vivo anti-infection properties of HACC-loaded TNTs.The nanotubular structure of the NT-C and NT-H groups remained intact after the implantation,as displayed at high magni f i cation,which indicated in vivo stability of the nanotubes,and therefore provides reliable evidence for the viability of drug-loaded nanotube implants in orthopedic surgery.
In summary,our study demonstrated that HACC-loaded nanotubes on titanium implants exhibited obvious antiinfection potential in vivo and good osteoactivity in vitro when compared with Ti and NT-C.The nanotube structure and surface characteristics exhibited limited antimicrobial effects on the implant-associated infections in vivo.
This research was f i nancially supported by the National Natural Science Foundation of China(No.31271015,81501856),National Key R&D Program (2016YFC1102100),the Shanghai Science and Technology Development Fund (13JC1403900,13DZ2294000),and the Medical Engineering Collaborative Project of Shanghai Jiao Tong University(YG2014ZD01).
The authors declare no con f l ict of interest.
1 Court-Brown C M,Keating JF,McQueen MM.Infection after intramedullary nailing of the tibia.Incidence and protocol for management. J Bone Joint Surg Br 1992;74:770–774.
2 Chen CE,Ko JY,Wang JW et al.Infection after intramedullary nailing of the femur.J Trauma 2003;55:338–344.
3 Court-Brown CM.Reamed intramedullary tibial nailing:an overview and analysis of 1106 Cases.J Orthop Trauma 2004;18:96–101.
4 Birdsall PD,Milne DD.Toxic shock syndrome due to percutaneous Kirschner wires.Injury 1999;30:509–510.
5 Losic D,Aw MS,Santos A et al.Titania nanotube arrays for local drug delivery:recent advances and perspectives.Expert Opin Drug Deliv 2015; 12:103–127.
6 Gulati K,Aw MS,Losic D.Drug-eluting Ti wires with titania nanotube arrays for bone f i xation and reduced bone infection.Nanoscale Res Lett 2011;6:571.
7 Popat KC,Eltgroth M,LaTempa TJ et al.Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibioticloaded titania nanotubes.Biomaterials 2007;28:4880–4888.
8 Peng Z,Ni J,Zheng K et al.Dual effects and mechanism of TiO2 nanotube arrays in reducing bacterial colonization and enhancing C3H10T1/2 cell adhesion.Int J Nanomedicine 2013;8:3093–3105.
9 Ercan B,Taylor E,Alpaslan E et al.Diameter of titanium nanotubes in f l uences anti-bacterial ef f i cacy.Nanotechnology 2011;22:295102.
10 Wang N,Li H,Lu W et al.Effects of TiO2 nanotubes with different diameters on gene expression and osseointegration of implants in minipigs.Biomaterials 2011;32:6900–6911.
11 Gong T,Xie J,Liao JF et al.Nanomaterials and bone regeneration. Bone Res 2015;3:15029.
12 Barth E,Myrvik QM,Waqner W et al.In vitro and in vivo comparative colonization of Staphylococcus aureus and Staphylococcus epidermidis on orthopaedic implant materials.Biomaterials 1989;10:325–328.
13 Lin WT,Tan HL,Duan ZL et al.Inhibited bacterial bio f i lm formation and improved osteogenic activity on gentamicin-loaded titania nanotubes with various diameters.Int J Nanomedicine 2014;9:1215–1230.
14 Yang Y,Ao HY,Yang SB et al.In vivo evaluation of the anti-infection potential of gentamicin-loaded nanotubes on titania implants. Int J Nanomedicine 2016;11:2223–2234.
15 Baquero F.Gram-positive resistance:challenge for the development of new antibiotics.J Antimicrob Chemother 1997;39:1–6.
16 Campoccia D,Montanaro L,Arciola CR.The signi f i cance of infection related to orthopedic devices and issue of antibiotic resistance.Biomaterials 2006;27:2331–2339.
17 Rabea EI,Badawy ME,Stevens CV et al.Chitosan as antimicrobial agent: applications and mode of action.Biomacromolecules 2003;4:1457–1465.
18 Li F,Liu WG,Yao KD.Preparation of oxidized glucose-crosslinked Nalkylated chitosan membrane and in vitro studies of pH-sensitive drug delivery behaviour.Biomaterials 2002;23:343–347.
19 Qin C,Xiao Q,Li H et al.Calorimetric studies of the action of chitosan-N-2-hydroxypropyl trimethyl ammonium chloride on the growth of microorganisms.Int J Biol Macromol 2004;34:121–126.
20 Marcotte L,Barbeau J,La f l eur M.Permeability and thermodynamics study of quaternary ammonium surfactants-phosphocholine vesicle system.J Colloid Interface Sci 2005;292:219–227.
21 Crismaru M,Asri LA,Loontjens TJ et al.Survival of adhering Staphylococci during exposure to a quaternaryammonium compound evaluated by using atomic force microscopy imaging.Antimicrob Agents Chemother 2011;55:5010–5017.
22 Tan HL,Peng ZX,Li QT et al.The use of quaternised chitosan-loaded PMMA to inhibit bio f i lm formation and downregulate the virulenceassociated gene expression of antibiotic-resistant staphylococcus.Biomaterials 2012;33:365–377.
23 Tan HL,Ao HY,Ma R et al.In vivo effect of quaternized chitosan-loaded polymethylmethacrylate bone cement on methicillin-resistant Staphylococcus epidermidis infection of the tibial metaphysis in a rabbit model. Antimicrob Agents Chemother 2014;58:6016–6602.
24 Lin WT,Zhang YY,Tan HL et al.Inhibited bacterial adhesion and bio f i lm formation on quaternized chitosan-loaded titania nanotubes with various diameters.Materials 2016;9:155.
25 Ao HY,Xie YT,Yang SB et al.Covalently immobilised type I collagen facilitates osteoconduction and osseointegration of titanium coated implants.J Orthop Trans 2016;5:16–25.
26 Ma R,Tang SC,Tan HL et al.Preparation,characterization,in vitro bioactivity,and cellular responses to a polyetheretherketone bioactiviecomposite containing nancalcium silicate for bone reapair.ACS Appl Mater Interfaces 2014;6:12214–12225.
27 Sun W,Zhang K,Liu G et al.Sox9 gene transfer enhanced regenerative effect of bone marrow mesenchymal stem cells on the degenerated intervertebral disc in a rabbit model.PLoS One 2014;9:e93570.
28 Lucke M,Schmidmaier G,,Sadoni S et al.Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats.Bone 2003; 32:521–531.
29 Qin H,Zhao Y,An Z et al.Enhanced antibacterial properties, biocompatibility,and corrosion resistance of degradable Mg-Nd-Zn-Zr alloy.Biomaterials 2015;53:211–220.
30 Zhang G,Guo B,Wu H et al.A delivery system targeting bone formation surfaces to facilitate RNAi-based anabolic therapy.Nat Med 2012; 18:307–314.
31 Rissing JP,Buxton TB,Weinstein RS et al.Model of experimental chronic osteomyelitis in rats.Infect Immun 1985;47:581–586.
32 Zhao L,Chu PK,Zhang Y et al.Antibacterial coatings on titanium implants.J Biomed Mater Res B Appl Biomater 2009;91:470–480.
33 Cordero J,Munuera L,Folgueira MD.In f l uence of bacterial strains on bone infection.J Orthop Res 1996;14:663–667.
34 Southwood RT,Rice JL,McDonald PJ et al.Infection in experimental hip arthroplasties.J Bone Joint Surg Br 1985;67:229–231.
35 Gristina AG.Implant failure and the immuno-incompetent fi broin fl ammatory zone.Clin Orthop Relat Res 1994;298:106–118.
36 Schierholz JM,Beuth J.Implant infections:a haven for opportunistic bacteria.J Hosp Infect 2001;49:87–93.
37 Neoh KG,Hu X,Zheng D et al.Balancing osteoblast functions and bacterial adhesion on functionalized titanium surfaces.Biomaterials 2012; 33:2813–2822.
38 Doyle RJ.Contribution of the hydrophobic effect to microbial infection. Microbes Infect 2000;2:391–400.
39 Chang Y,Chen S,Yu Q et al.Development of biocompatible interpenetrating polymer networks containing a sulfobetaine-based polymer and a segmented polyurethane for protein resistance.Biomacromolecules 2007;8:122–127.
40 Maximous N,Nakhla G,Wan W.Comparative assessment of hydrophobic and hydrophilic membrane fouling in wastewater applications. J Membrane Sci 2009;339:93–99.
41 Krasowska A,Sigler K.How microorganisms use hydrophobicity and what does this mean for human needs?Front Cell Infect Microbiol 2014;4:112.
42 Pasmore M,Todd P,Smith S et al.Effects of ultra f i ltration membrane surface properties on Pseudomonas aeruginosa bio f i lm initiation for the purpose of reducing biofouling.J Membrane Sci 2001;194:15–32.
43 Akesso L,Navabpour P,Teer D et al.Deposition parameters to improve the fouling-release properties of thin siloxane coatings prepared by PACVD.Appl Surf Sci 2009;255:6508–6514.
44 Navabpour P,Teer D,Su X et al.Optimisation of the properties of siloxane coatings as anti-biofouling coatings:comparison of PACVD and hybrid PACVD–PVD coatings.Surf Coat Technol 2010;204:3188–3195.
45 Foss BL,Ghimire N,Tang R et al.Bacteria and osteoblast adhesion to chitosan immobilized titanium surface:a race for the surface.Colloids Surf B Biointerfaces 2015;134:370–376.
46 Yuan S,Yin J,Jiang W et al.Enhancing antibacterial activity of surfacegrafted chitosan with immobilized lysozyme on bioinspired stainless steel substrates.Colloids Surf B Biointerfaces 2013;106:11–21.
47 Zhao L,Hu Y,Xu D et al.Surface functionalization of titanium substrates with chitosan–lauric acid conjugate to enhance osteoblasts functions and inhibit bacteria adhesion.Colloids Surf B Biointerfaces 2014;119:115–125.
This work is licensed under a Creative Commons Attribution 4.0 International License.The images or other third party material in this article are included in the article’s Creative Commons license,unless indicated otherwise in the credit line;if the material is not included under the Creative Commons license,users will need to obtain permission from the license holder to reproduce the material.To view a copy of this license,visit http://creativecommons.org/licenses/by/4.0/
©The Author(s)2016
Research(2016)4,16027;
10.1038/boneres.2016.27;published online:20 September 2016
Shanghai Key Laboratory of Orthopedic Implants,Department of Orthopedic Surgery,Shanghai Ninth People’s Hospital,Shanghai Jiao Tong University,School of Medicine,Shanghai,People’s Republic of China
Correspondence:Ting-ting Tang(ttt@sjtu.edu.cn)
Received:13 May 2016;Revised:29 June 2016;Accepted:11 July 2016
我们致力于保护作者版权,注重分享,被刊用文章因无法核实真实出处,未能及时与作者取得联系,或有版权异议的,请联系管理员,我们会立即处理! 部分文章是来自各大过期杂志,内容仅供学习参考,不准确地方联系删除处理!