Abstract:The modeling approaches of power converters occupy an important position in power electronic systems and have made considerable progress over the past years.Continuous modeling approaches and linearization techniques are reviewed,including the state-space average model,generalized average model,averaged small-signal model,and describing function method.A Buck converter with PWM modulation and voltage-mode control is taken as an example to compare the advantages and disadvantages of different methods through simulation analysis.Moreover,the corresponding equivalent circuit with an intuitive physical meaning of state-space average model,generalized average model,and averaged small-signal model is given.The results point out that the generalized average model can improve the modeling accuracy based on the state-space average model.In the linearization techniques,the averaged small-signal model reflects accuracy at low frequencies,but introduces phase lag in the high-frequency region.The describing function method is derived from harmonic linearization,which takes into account the sideband effect and improves the modeling accuracy at high frequencies.
Keywords:State-space average model,generalized average model,linearization techniques,averaged small-signal model,describing function method
Modeling approaches are the basis to study the characteristics and control approaches of power converters.A power converter with PWM modulation is a switching system with nonlinear and time-varying characteristics.In view of this characteristics,many studies have been performed on its modeling approaches and system analysis in academia and industry.Generally,there are two ways to deal with the time-varying dynamics of converters.One way is to model the converter as a discrete system,and the other way is to model the converter as a continuous system.This paper reviews and compares the commonly used continuous modeling approaches to analyze power converters[1-3].
The average modeling approaches are widely used to average out the switching dynamics in power converters.Some of the utility of the average modeling approaches for simulation purposes,using dedicated software products such as SPICE®,SABER®,and MATLAB®,has also been widely proved[1].Wester et al.[4]first proposed a modeling method based on the concept of the circuit average.One of the most representative average modeling approaches is the state-space average model,which was introduced by Middlebrook et al.[5]in 1976.The state-space averaged model has been shown to have limited utility for stability prediction when the feedback signals have high switching-frequency ripple,such as in the case of peak-current control[6]and state feedback control[7-8].Chetty[9]proposed the current injected equivalent circuit approach to model switching DC-DC converters.Czarkowski et al.[10]used the energy conservation method to model the DC-DC converter by considering the power loss.In order to consider the switching ripple,some extended methods appear.Krein et al.[11-12]developed the Krylov-Bogoliubov-Mitropolsky (KBM) method according to the approximation method by discontinuity points.Sanders et al.[13-14]proposed generalized average modeling method based on Fourier analysis.These approaches not only can improve the modeling accuracy,but also can be applied to the resonant converter[14].However,the achieved model is usually complicated and cannot be used in engineering design.These extended methods focus on the approximation of the original system equation of state and have a complete mathematical structure.
Linearization technology generally refers to a nonlinear system near a given steady operating point with small-signal disturbances,just as in the averaged small-signal model[15-16].The averaged small-signal model is a good tool for practical controller design for industrial and engineering application.However,this model ignores the switching ripple effect and introduces phase lag in the high-frequency region.Therefore,the averaged small-signal model has been shown to have limited utility for stability prediction when the feedback signals have high switching-frequency ripple[17-18].
In addition,the describing function method is recently developed.In the early stage,Middlebrook et al.[19-20]studied the frequency characteristics of current-mode controlled switching converters based on the modeling idea of averaging the inductor current in a switching cycle,but they failed to accurately predict the sub-harmonic oscillation of the system.On this basis,Ridley[21]considered the influence of the sample hold link in the peak current control to obtain an improved average model.Ref.[22]established a multi-frequency model based on the analysis of the nonlinear characteristics of the pulse width modulator,considering the voltage outer loop and ignoring the sideband frequency effect of the inductor current.Aiming at the problem that the improved average model cannot accurately model the frequency conversion control.Yan et al.[23-25]proposed a modeling method based on the described function and obtained the equivalent circuit model with the improved three-terminal switch model on this basis.The model can be used to reveal the high-frequency information of the switching converter with V2control[26-27].This is used to model the LLC converter to obtain the small-signal model according to the basic circuit equation and harmonic balance principle[28-30].
The paper is organized as follows.Section 2 discusses the operating state of the power converters with different switching state by using the switching function.Section 3 introduces the average modeling methods and limitations of the state-space average model,generalized average model.Section 4 demonstrates the average small-signal model and Section 5 introduces the describing function method.Finally,the four discussed types of models are compared with each other and the conclusion of this paper is given in Section 6.
In order to describe the modeling methods of converter system,a closed-loop voltage-mode controlled continuous conduction mode (CCM) Buck converter with PWM modulation is selected as an example.The topology of converter is shown in Fig.1.The parameters of the power stage and controller are summarized in Tab.1.
Fig.1 Voltage mode controlled Buck converter
Tab.1 Power stage parameters
As can be seen from Fig.1,in a switching periodTand duty ratiodof the converter,there are two working states of the system.The working states are driven by signalδ(t),called the switching function,which is
When the duty ratiod=ton/T(Tis the switching period)is constant,the waveform of the switch function is as shown in Fig.2.
Fig.2 The waveform of the switch function
According to the switch functionδ(t),there are two states when the switch works in on and off states respectively.Selecting filter inductance currentiLand output voltagevoas state variables,the state equation of the power stage can be expressed as
The state Eq.(2) is a time-varying and discontinuous system.Due to the existence of the switching function,the system cannot be directly applied to the closed-loop controller design.Therefore,some equivalent methods should be applied to obtain the system’s small-signal model so that the feedback system controller can be designed.
Generally,in order to provide good performance of the system,the control laws need to be designed,then the discontinuous system needs to be converted to a continuous system.Furthermore,it is desired to obtain a model that is easy to use[1].For this reason,the average modeling methods are proposed.
State-space average model was widely used in modeling of PWM converters.However,this modeling method needs to operate under the conditions of low frequency,small ripple,and small-signal hypothesis[4].The moving-average operator is a useful tool to eliminate the switching ripple.xis defined as the state valuable.Then the average value ofxin each witching period by using the average operator can be expressed as
A generic power electronic converter is described as a dynamic system
whereAnis input state variable coefficient matrix andBnis output state variable coefficient matrix.Applying the moving average operator to the dynamic system in Eq.(4),the state-space average model of the power converter can be summarized as follows through the above examples
wheremis the number of topology changes in a switching period.According to Eq.(5),the state-space average model of nonlinear switching functionδ(t) can be expressed as the duty ratiod.Applying Eq.(5) to the Buck converter state equation in Eq.(2),the matrix parameters can be expressed as
The model in Eq.(5) is the analytical approach,which cannot directly express the physical meaning of the circuit[5].Therefore,the equivalent circuit topological diagram,as shown in the Fig.3,where the coupling terms are emphasized and from which a power converter equivalent model can also be obtained,is established.
Fig.3 Average model equivalent circuit of Buck converter
Therefore,the waveform curve of the average model can be calculated by the equivalent circuit or the state-space average equation directly.Fig.4 presents a comparison between the detailed switching converter and the averaged behavior of the converter,and the time evolution of state variables,i.e.,the inductor currentiLand output voltagevo,are shown.
Among the advantages of the state-space average model,in particular is the ease of building and implementing the model and ability to assess the dynamic characteristics.Besides,the model is not useful for resonant converters.
Fig.4 The simulation waveform of the output voltage and inductance current:State-space average model and detailed switching converter
To consider the switching ripple effect,Prof.George Verghese from Massachusetts Institute of Technology (MIT) proposed generalized average model based on Fourier analysis[13-14].The generalized average model is a more ideal modeling method than the state-space average model.This model can approximate the time-domain model to the required accuracy and can accurately analyze the transient process of power converters.
The core idea of the generalized average model is to describe the periodic signal in the time domain by using Fourier series and linearize the nonlinear part.Therefore,the periodic variablex(t) can be expressed as
whereω=2πfsis the fundamental pulsation and <x>(k)is the Fourier coefficient of thekth component,which is given by
Becausekrepresents a harmonic component,the modeling result will be more accurate askincreases.However,this greatly increases the amount of calculations.Fig.5 shows the Eq.(8) applied to the switching functionδ(t) with different Fourier series.Modeling results become much more accurate when more harmonics are involved.
Fig.5 Different Fourier-series harmonic component of the switch function
Applying the Fourier series Eq.(8) to Eq.(2),the generalized average model of Buck converter can be expressed as
For calculation convenience,most existing literature chooses the DC component and the first-order harmonic component[13],that is,the cases ofk=0 andk=1 are considered.Similarly,by applying discrete convolution and conjugation properties to Eq.(9),the generalized average model can be got through the state equation expressions of DC component and first-order harmonic component.Afterwards,an analytical solution can be obtained by solve the two state equations to obtain[14],which will not be detailed here.
The equivalent circuit of the first-order harmonic component Eq.(9) can be obtained,as shown in Fig.6.
Fig.6 Equivalent diagram of first-order harmonic component of Buck converter
From the first-order harmonic component results,as shown in Fig.6,the AC impedances are emphasized.One need only write Kirchhoff’s equations by using Fig.6 to obtain the analytical model equal to Eq.(9)and finalize the computation by calculating the real and imaginary parts of the complex variables to obtain the generalized average model final form of the Buck converter.The results of applying the generalized average model to the to the Buck converter topology are shown in Fig.7.
Fig.7 The simulation waveform of the output voltage and inductive current:generalized average model and detailed switching converter
The simulation results show that the generalized average model is characterized by considering the AC characteristics of the switching system.Therefore,its order is higher than that of the average model,and its accuracy is higher.However,because this method only considers some harmonic components and fails to reflect all AC characteristics,its accuracy and complexity need to be considered comprehensively.
In order to complete the feedback control design of the converter system using the classical control theory of linear systems,it is necessary to further adopt the small-signal perturbation method to linearize the above nonlinear equation near a given static operating point[2].
The averaged small-signal model is based on the small-signal perturbation method to linearize the nonlinear equation near a static operating point.The converter is assumed to work at a certain steady-state operating point with the duty cycleD,inductor currentIL,input voltageVgand output voltageVo.For the average model of Buck converter,supposing a low-frequency small disturbance near the steady-state operating point gives
The averaged small-signal model of the Buck converter can be rewritten as
Similarly,a more intuitive small-signal equivalent circuit model can be established according to the average small-signal model,which provides convenience for analyzing the small-signal characteristics of the converter.Fig.8 shows a small-signal equivalent circuit of the Buck converter.
Fig.8 The small-signal equivalent circuit of the Buck converter
Fig.8 intuitively reflects the small-signal treating processes of the Buck converter.To further analyze the low frequency dynamic characteristics of the converter,the input-output transfer functionGvg,the control-output transfer functionGvd,and the output impedanceZo,can be derived as follows
In addition,it is known that the input perturbation of the PWM comparator varies slowly compared with the switching frequency[5].So,the transfer function of the PWM comparator can be expressed as
Therefore,the control system block diagram of the average small-signal model for a voltage mode controlled Buck converter can be obtained,as shown in Fig.9.
Fig.9 The control system block diagram for voltage-mode controlled Buck converter
According to Fig.9,the loop gain of the voltage mode controlled switching converter can be obtained whereGc(s) is the compensator with a PI controller andH(s) is the feedback[7].The closed-loop feedback control,input-output,output impedance,and output impedance closed-loop transfer function are expressed as
The above formula shows that the influence of the input voltage or load disturbance on the output voltage can be effectively suppressed by increasing the loop gainT(s).Fig.10 shows the frequency response of the loop gain of a voltage-mode controlled Buck converter.
Fig.10 Loop gain of a voltage mode controlled Buck converter
Obviously,the averaged small-signal model introduces phase lag in the high-frequency region.The averaged small-signal model eliminated the switching ripple effect and the modeling results is questionable at high frequencies because of linearization and time-invariant assumptions,so it can only extract the low-frequency small-signal characteristics of the system.
It is known that the switching devices in the power converter and the PWM link in the control loop make the system exhibit nonlinear characteristics[2].When a small-signal disturbance with frequencyfxis injected into the input voltagevg(t) and modulation linkvc(t),the switching network output voltagevd(t)and switching functionδ(t) not only contain disturbance frequency components[20],but also are affected by the sideband effect shown in Fig.11.
Fig.11 Sideband effect generated by the switching frequency domain waveforms
Fig.12 reveals the multi-frequency characteristics of the voltage mode controlled Buck converter from the perspective of the frequency domain.Therefore,it is necessary to consider the sideband effect in the system.The diagram becomes the small-signal averaged model in Fig.8 if only the perturbation frequency component (marked by bold blue lines) is involved in the modeling.
Fig.12 Multi-frequency input and multi-frequency output relationship of closed-loop controlled switching converter
The error of the small-signal average modeling method at high frequencies is mainly due to the sideband effect of the switching modulation.In order to improve the accuracy of modeling,some frequency-domain modeling methods considering the sideband effect are proposed,among which,the describing function method provides an effective solution for modeling the sideband effect[23].
The essence of the describing function method is a harmonic balance method based on Fourier series.Generally,if the input to a nonlinear system is a sinusoidal function
When a disturbance with frequencyfx=ω/2π occurs,the describing function expression of the input and output at the disturbance frequency is as follows
In voltage mode controlled Buck converters,a describing function method is proposed to explain the measured phase delay of the loop gain by considering the sideband effect of PWM comparator[26],which is
whereTdf(fx) is the loop gain of a voltage mode controlled Buck converter.The influence from the sideband effect is shown in the denominator.According to the previous analysis,the sideband effect has a greater impact on the high-frequency range.
Fig.13 shows a bode diagram of the loop gains of a closed loop controlled Buck converter obtained by simulation.Compared with the average small-signal model,the describing function method considers the influence of sideband effect from the perspective of the frequency domain,so it improves the accuracy of the model.Therefore,for stability analysis at highfrequency cases,it is necessary to use the describing function method to replace the average model.
Fig.13 Loop gain of a voltage mode controlled Buck converter
The describing function method has been developed recently.Another application of the describing function method is to analyze the small-signal model of the resonant converter because when many inverters are connected to the AC grid,the describing function method can be used to analyze the small-signal model of the resonant inverter[30]and LLC resonant[29]converter system.The nonlinear part of the resonant converter is approximately linearized by using the principle of extended describing function.After that,the small-signal model of the resonant converter can be obtained according to the basic circuit equation and harmonic balance principle[28].
The modeling methods of power electronic converters are the theoretical basis of switching power design.Existing modeling methods are numerous and lack overall introductions.This paper systematically classifies and summarizes various modeling methods in continuous mode,and the comparison results of different modeling methods are listed in Tab.2.Moreover,the corresponding equivalent circuit with an intuitive physical meaning of the state-space average model,generalized average model,and averaged small-signal model is given.Through this paper,researchers and engineers may gain a comprehensive understanding of the modeling theory.Thus,effective design guidelines can be selected quickly for different kinds of converters.
Tab.2 Comparison of different modeling methods
One of the advantages of the state-space average model is that it is easy to establish and implement,and it has good approximation accuracy when predicting low-frequency information.In contrast,when high-frequency information cannot be ignored,the accuracy of the model begins to decline.In addition,the model is not useful for resonant converters.
The generalized average model proves to be a more accurate model than the state-space average model because the switching ripple is considered.However,due to the increase in state variables,the complexity of the system also increases.
The averaged small-signal model is a good tool for engineering controller design.However,this model ignores the switching ripple effect and introduces phase lag in the high-frequency region.
The describing function method can accurately predict the sub-harmonic oscillation in the switching power supply due to the influence of the sideband frequency,and it can accurately analyze the frequency-domain characteristics of the constantfrequency (PWM and phase shift) or variablefrequency power converter,but the modeling process of the describing function method is more complicated.
The above modeling methods have their respective advantages and disadvantages.In general,a tradeoff should be made in terms of modeling accuracy and calculation complexity.